Products
GPS Surveying Systems
GPS/GIS Data Collectors
GPS Reference Networks
Surveying & Engineering
Scanners
Software
Accessories
Automatic (Optical) Levels
Digital & Electronic Levels
General Construction
Interior Lasers
Machine Control Lasers
Laser Detectors
|
TPS400
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Leica TC403/5/7 | -Distance Measurement on Reflector (IR) |
| Leica TCR403/5/7 power | -Distance Measurement on Reflector (IR) -PinPoint R400 Reflectorless Distance Measurement (RL) |
| Leica TCR403/5/7 ultra | -Distance Measurement on Reflector (IR) -PinPoint R1000 Reflectorless Distance Measurement (RL) |
| Technical data | TPS 403 | TPS 405 | TPS 407 |
| Angle measurements (Hz, V) | |||
| Method | Absolute continuous | ||
| Display resolution | 1" / 0.1mgon / 0.01 mil | ||
| Standard deviation (ISO 17123-3) | 3" (1mgon) | 5" (1.5mgon) | 7" (2mgon) |
| Telescope | |||
| Magnification | 30 x | ||
| Field of view | 1° 30' (26 m at 1 km) | ||
| Min. target distance | 1.7m | ||
| Reticle | illuminated | ||
| Compensator | |||
| System | Electronic 2 axis oil compensator | ||
| Setting accuracy | 1" | 1.5" | 2" |
| Distance Measurement on Reflector (IR) | |||
| Measuring range with circular prism GPR1 | 3,500m | ||
| Measuring with reflective foil (60mm x 60mm) | 250m | ||
| Standard deviation (ISO 17123-4) (fine/quick/tracking) | 2mm + 2ppm/5mm + 2ppm/5mm + 2ppm | ||
| Time for a measurement (fine/quick/tracking) | typ. 2.4 sec/0.8 sec/< 0.15 sec | ||
| PinPoint-Reflectorless Distance measurement (RL) | |||
| Range: | PinPoint R400 ("power") > 400 m (90% reflective) | ||
| (Medium atmospheric conditions) | PinPoint R1000 ("ultra") > 1000 m (90% reflective) | ||
| Laser at GPR circular reflector 7,500m | |||
| Standard deviation (ISO 17123-4) | 0-500m 2mm+2 ppm > 500m 4mm+2 ppm |
||
| Time per meas. | typ. 3 - 6s, max. 12s | ||
| Point size at 100m | 12 mm x 40mm | ||
| Communication | |||
| Internal data storage | 12,500 measurements or 18,000 fixpoints | ||
| Interface | RS232 | ||
| Data formats | GSI/IDEX/ASCII/DXF/Freely definable formats | ||
| Operation | |||
| Display | Graphics 160 x 280 pixels, | ||
| Alphanumeric 8 lines x 31 characters | |||
| Laser plummet | |||
| Type | Laser point, brightness adjustable in steps | ||
| Accuracy | 1.5mm at 1.5m instrument height | ||
| Environmental conditions | |||
| Temperature range (operation) | -20° C to +50° C (-4° F to +122° F) | ||
| Dust and splash proof (IEC 60529) | IP55 | ||
| Humidity | 95 %, non condensing | ||
| Weight | |||
| Weight including battery and tribrach | 5.2 kg | ||
| Operating period with GEB121 | approx. 6 hours | ||
| Number of distance measurements with GEB121 | approx. 9,000 | ||